McDATA®Sphereon™ 4300 Fabric SwitchInstallation and Service ManualP/N 620-000171-030REV A
xMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualTables
3-36McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures• Event code 142 - OpenTrunking firmware detected
Maintenance Analysis Procedures3-37Maintenence Analysis Procedures23A zone merge process failed during ISL initialization. The following list explains
3-38McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis ProceduresObtain supplementary error code data for event co
Repair Information4-14Repair InformationThis chapter describes repair-related procedures for the Sphereon 4300 Fabric Switch. The procedures are perfo
4-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationPower On SwitchTo power on the switch:1. An alternating current
Repair Information4-3Repair InformationPower Off SwitchTo power off the switch:1. Inform the customer the switch is to be powered off. Ensure the syst
4-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationIMLTo IML the switch:1. Press and hold the IML/RESET button (ab
Repair Information4-5Repair InformationCAUTIONWear eye protection when using an aerosol duster.To clean fiber-optic components:1. Optical transceivers
4-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationDownload Firmware from the FilecenterThe firmware version shipp
Repair Information4-7Repair Information4. Select (click) Documents at the top of the page. The Search / New Documents / By Category page displays.5. S
PrefacexiPrefaceThis publication is part of a documentation suite that supports the McDATA® Sphereon 4300 Fabric Switch.Who Should Use thisManualUse t
4-8McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationPort LED DiagnosticsFibre Channel port diagnostic information i
Repair Information4-9Repair InformationRepair Procedures - EFCM Basic EditionThe following procedures (performed at a PC communicating with the EFCM B
4-10McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationEvent Log The Event Log records events or errors. Entries refl
Repair Information4-11Repair Information• Old Exit Port - Port number (decimal) transmitting Fibre Channel traffic before the re-route.• New Exit Port
4-12McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationPerform Port DiagnosticsFibre Channel port diagnostic informat
Repair Information4-13Repair Information• Operational State - Port state (Online, Offline, Not Installed, Inactive, Invalid Attachment, Link Reset, No
4-14McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair Information• FAN Configuration - User-configured state for fabric address
Repair Information4-15Repair Information• Media - Type of optical cable used (Singlemode, multimode 50-micron, multimode 62.5-micron, or Unknown).• Sp
4-16McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair Information2. At the EFCM Basic Edition interface, select Ports and Diagn
Repair Information4-17Repair Informationb. For the tested port, click (enable) the check box in the Reset column. A check mark in the box indicates th
xiiMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualPrefaceChapter 4, Repair Information - This chapter describes supplementary diagn
4-18McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair Information10. Reset the tested port:a. Select Ports and Reset from the M
Repair Information4-19Repair Information2. Right-click the Data Collection link to open a list of menu options. Select the Save Target As menu option.
4-20McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationFigure 4-6 Switch View2. Perform one of the following:— If the
Repair Information4-21Repair InformationFigure 4-7 Basic Information View2. Perform one of the following:— Click the check box for the selected port i
4-22McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationDetermine Firmware VersionTo determine a firmware version, sel
Repair Information4-23Repair Information2. At the Download Firmware file from field, select the desired file from the PC hard drive using the Browse b
4-24McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair InformationBack UpConfigurationTo back up the switch configuration file t
Repair Information4-25Repair InformationFigure 4-10 Restore Configuration View4. At the Download Configuration file from field, select the desired fil
4-26McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRepair Information6. The switch IP address resets to the default address of 10.1
Removal and Replacement Procedures5-15Removal andReplacement ProceduresThis chapter describes field-replaceable unit (FRU) removal and replacement pro
PrefacexiiiPrefaceWhere to Get Help For technical support, contact the McDATA solution center. The center provides a point of contact for assistance a
5-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRemoval and Replacement ProceduresESD ProceduresFollow these ESD procedures:• If
Removal and Replacement Procedures5-3Removal and Replacement ProceduresRRP 1: SFP Optical TransceiverUse the following procedures to remove or replace
5-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRemoval and Replacement Procedures6. Disconnect the fiber-optic jumper cable from
Removal and Replacement Procedures5-5Removal and Replacement Procedures4. Perform an external loopback test. Refer to External Loopback Test for instr
5-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualRemoval and Replacement Procedures
Illustrated Parts Breakdown6-16Illustrated PartsBreakdownThis chapter provides an illustrated parts breakdown for Sphereon 4300 Switch field-replaceab
6-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualIllustrated Parts BreakdownFront-Accessible FRUsFigure 6-1 illustrates front-acce
Illustrated Parts Breakdown6-3Illustrated Parts BreakdownMiscellaneous PartsFigure 6-2 illustrates miscellaneous parts. Table 6-2 is the associated pa
6-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualIllustrated Parts BreakdownPower Cords and ReceptaclesFigure 6-3 illustrates opti
Illustrated Parts Breakdown6-5Illustrated Parts BreakdownTable 6-3 Power Cord and Receptacle ListRef. Part Number Description Feature-1 806-000001-000
xivMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualPrefaceLaser ComplianceStatementProduct laser transceivers are tested and certifi
6-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualIllustrated Parts Breakdown-12 806-000040-000 Power cord, AC, United States (Chic
Event Code TablesA-1AEvent Code TablesAn event is a state change, problem detection, or problem correction that requires attention or should be report
A-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code Tables— 0 - informational.— 2 - minor.— 3 - major.— 4 - severe (not op
Event Code TablesA-3Event Code TablesEvent Code: 021Message: Name Server database invalid.Severity: Minor.Explanation: Following an IML or firmware do
A-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 051Message: Management Server database invalid.Sever
Event Code TablesA-5Event Code TablesEvent Code: 062Message: Maximum interswitch hop count exceeded.Severity: Informational.Explanation: Fabric contro
A-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 064Message: ESS response from indicated domain ID no
Event Code TablesA-7Event Code TablesEvent Code: 070Message: E_Port is segmented.Severity: Informational.Explanation: An E_Port recognized an incompat
A-8McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 071Message: Switch is isolated.Severity: Information
Event Code TablesA-9Event Code TablesEvent Code: 072Message: E_Port connected to unsupported switch.Severity: Informational.Explanation: The switch is
PrefacexvPrefaceInternational SafetyConformityDeclaration (CBScheme)A certification bodies (CB) test report supporting a product indicates safety comp
A-10McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 074Message: ILS frame delivery error threshold exce
Event Code TablesA-11Event Code TablesEvent Code: 080Message: Unauthorized worldwide name.Severity: Informational.Explanation: The WWN of the connecte
A-12McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 081Message: Invalid attachment.Severity: Informatio
Event Code TablesA-13Event Code TablesEvent Code: 081 (continued)Event Data (continued):A = Unauthorized port binding WWN - The device WWN or nickname
A-14McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 082Message: Port fenced.Severity: Informational.Exp
Event Code TablesA-15Event Code TablesEvent Code: 083Message: Port set to inactive state.Severity: Informational.Explanation: A hardware or software p
A-16McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 120Message: Error detected while processing system
Event Code TablesA-17Event Code TablesEvent Code: 140Message: Congestion detected on an ISL.Severity: Informational.Explanation: OpenTrunking firmware
A-18McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 142Message: Low BB_Credit detected on an ISL.Severi
Event Code TablesA-19Event Code TablesEvent Code: 150Message: Fabric merge failure.Severity: Informational.Explanation: During ISL initialization, the
xviMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualPreface• Products conform with all protection requirements of EU directive 73/23/
A-20McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 151Message: Fabric configuration failure.Severity:
Event Code TablesA-21Event Code TablesFan Events (300 through 399)Event Code: 300Message: Cooling fan propeller failed.Severity: Major.Explanation: On
A-22McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 302Message: Cooling fan propeller failed.Severity:
Event Code TablesA-23Event Code TablesEvent Code: 311Message: Cooling fan propeller recovered.Severity: Informational.Explanation: Two cooling fans re
A-24McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 370Message: Cooling fan status polling temporarily
Event Code TablesA-25Event Code TablesCTP Card Events (400 through 499)Event Code: 400Message: Power-up diagnostics failure.Severity: Major.Explanatio
A-26McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 411Message: Firmware fault.Severity: Major.Explanat
Event Code TablesA-27Event Code TablesEvent Code: 421Message: Firmware download complete.Severity: Informational.Explanation: A new firmware version w
A-28McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 426Message: Multiple ECC single-bit errors occurred
Event Code TablesA-29Event Code TablesEvent Code: 440Message: Embedded port hardware failed.Severity: Major.Explanation: The embedded port hardware de
PrefacexviiPrefacePeople’s Republic ofChina CCC MarkThe China Compulsory Certification mark (CCC mark) on a product indicates compliance with People’s
A-30McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 445Message: ASIC detected a system anomaly.Severity
Event Code TablesA-31Event Code TablesPort Events (500 through 599)Event Code: 506Message: Fibre Channel port failure.Severity: Major.Explanation: A F
A-32McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 508Message: Fibre Channel port anomaly detected.Sev
Event Code TablesA-33Event Code TablesEvent Code: 512Message: Optical transceiver nonfatal error.Severity: Minor.Explanation: Switch firmware detected
A-34McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 514Message: Optical transceiver failure.Severity: M
Event Code TablesA-35Event Code TablesEvent Code: 516Message: Optical digital diagnostics alarm threshold exceeded.Severity: Minor.Explanation: An opt
A-36McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 524Message: No AL_PA acquired.Severity: Information
Event Code TablesA-37Event Code TablesEvent Code: 581Message: Implicit incident.Severity: Major.Explanation: An attached server recognized a condition
A-38McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesEvent Code: 583Message: Loss of signal or loss of synchronizati
Event Code TablesA-39Event Code TablesEvent Code: 585Message: Primitive sequence timeout.Severity: Major.Explanation: An attached server recognized ei
xviiiMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualPrefaceKorean MIC Mark The Korean Ministry of Information and Communications ma
A-40McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code TablesThermal Sensor Events (800 through 899)Event Code: 810Message:
Event Code TablesA-41Event Code TablesEvent Code: 812Message: CTP card shutdown due to thermal violations.Severity: Major.Explanation: The CTP card fa
A-42McDATA Sphereon 4300 Fabric Switch Installation and Service ManualEvent Code Tables
IndexI-1AAC power receptacle, location 1-3attention statements xviiiBback up switch configuration file 4-24BB_Creditconfigure 2-15description 2-1
McDATA Sphereon 4300 Fabric Switch Installation and Service ManualI-2IndexDdanger statements xviiidata collection procedure 4-18date (set switch dat
I-3IndexIndexMAP 0500 - Port failure or link incident analysis 3-16MAP 0600 - Fabric or ISL problem analysis 3-27summary 3-2fenced E_Portdescriptio
McDATA Sphereon 4300 Fabric Switch Installation and Service ManualI-4IndexLEDsERR 1-5port status 1-5power supply status 1-5PWR 1-5link incident lo
I-5IndexIndexpower supplydescription 1-4fault isolation 3-9status LED 1-5power-off procedure 4-3power-on procedure 4-2precautionsESD xxigeneral
McDATA Sphereon 4300 Fabric Switch Installation and Service ManualI-6IndexSphereon 4300 Fabric Switchdescription 1-1FRU removal and replacement 5-1F
PrefacexixPreface• Portuguese.•Spanish (European).• Spanish (Latin American).DANGERUse the supplied power cords. Ensure the facility power receptacle
McDATA Sphereon 4300 Fabric Switch Installation and Service ManualiiRecord of Revisions and UpdatesCopyright © 2002, 2005 McDATA Corporation. All righ
xxMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualPrefacePERICOLOUsare il cavo di alimentazione in dotazione. Assicurarsi che la pre
PrefacexxiPrefaceThe following ATTENTION statements appear in this publication and describe practices that must be observed while installing or servic
xxiiMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualPreface
General Information1-11General InformationThe McDATA® Sphereon™ 4300 Fabric Switch provides 12 ports of low-cost and high-performance dynamic Fibre Ch
11-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualGeneral Information• Expansion ports (E_Ports) to provide interswitch link (ISL)
1General Information1-3General InformationFigure 1-2 illustrates the rear of the switch and shows the:1. AC power receptacle.2. RS-232 maintenance por
11-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualGeneral InformationThe switch also provides a predictive optics monitoring (POM)
1General Information1-5General Information• Ethernet LAN interface, causing the connection to the management server to drop momentarily until the conn
11-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualGeneral InformationMaintenance PortThe rear panel has a 9-pin DSUB maintenance p
1General Information1-7General InformationStorage and ShippingEnvironmentProtective packaging must be provided to protect the switch under all shippin
ContentsiiiPreface ...xiChap
11-8McDATA Sphereon 4300 Fabric Switch Installation and Service ManualGeneral Information• Event information displays at a browser-capable PC communic
1General Information1-9General Information• A modular design that enables quick removal and replacement of FRUs without the use of tools or equipment.
11-10McDATA Sphereon 4300 Fabric Switch Installation and Service ManualGeneral InformationTools Supplied with the ProductThe following tools are suppl
1General Information1-11General Information• Null modem cable - An asynchronous RS-232 null modem cable (Figure 1-6) is required to configure product
11-12McDATA Sphereon 4300 Fabric Switch Installation and Service ManualGeneral Information— RS-232 serial communication software (such as ProComm Plus
Installation Tasks2-12Installation TasksThis chapter describes tasks to install, configure, and verify operation of the Sphereon 4300 Fabric Switch us
22-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksSummary of Installation TasksTable 2-2 summarizes installation
2Installation Tasks2-3Installation Tasks• Support is available for a browser-capable PC and Internet connectivity to support the product-resident EFCM
22-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksDesktop InstallationTo install a switch on a desktop:1. Remove
2Installation Tasks2-5Installation TasksRack-Mount InstallationPerform the following steps to install and configure the switch in a Fabricenter cabine
McDATA Sphereon 4300 Fabric Switch Installation and Service ManualivContentsTask 2: Unpack, Inspect, and Install the Product...2
22-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksTask 3: Configure Product at the EFCM Basic Edition InterfaceP
2Installation Tasks2-7Installation TasksFigure 2-1 Hardware ViewConfigure Product IdentificationPerform this procedure to configure the product identi
22-8McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasksa. Type a unique product name of 24 alphanumeric characters or
2Installation Tasks2-9Installation Tasksb. Click Time fields that require change, and type numbers in the following ranges:•Hour (HH): 0 through 23.•M
22-10McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasksb. At the Rerouting Delay field, check (enable) or uncheck (d
2Installation Tasks2-11Installation TasksConfigure Fabric ParametersPerform this procedure to configure fabric operating parameters.1. Set the product
22-12McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksPrincipal is the highest priority setting, Default is next, a
2Installation Tasks2-13Installation TasksFigure 2-6 Network View2. Click OK to save and activate changes. An acknowledgement message displays, indicat
22-14McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasks5. At the PC, launch the browser application (Netscape Naviga
2Installation Tasks2-15Installation Tasksc. Click the check box in the FAN column to enable or disable the fabric address notification (FAN) feature
vContentsContentsIML or Reset Switch...4-3IML...
22-16McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksConfigure Port NPIVNPIV allows multiple (up to 256) Fibre Cha
2Installation Tasks2-17Installation Tasksa. Click Enable to activate the installed SNMP agent.b. Select the appropriate Fibre Alliance management info
22-18McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksFigure 2-9 CLI ViewEnable or Disable Host ControlPerform this
2Installation Tasks2-19Installation Tasks3. Click (check) the Enable Host Control check box to activate host control of the product.4. Click OK to sav
22-20McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasks3. Software SSL enables use of an application program interfa
2Installation Tasks2-21Installation TasksKeys are encoded to work only with the serial number of the installed product. Record the key to re-install t
22-22McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation TasksFeature status is indicated by a green check markD(installed)
2Installation Tasks2-23Installation TasksTask 4: Configure Product Network Information (Optional)The product is delivered with default network address
22-24McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasks4. At the Windows Workstation menu, sequentially select the P
2Installation Tasks2-25Installation Tasks8. At the > prompt, type the user password (default is password) and press Enter. The password is case sen
McDATA Sphereon 4300 Fabric Switch Installation and Service ManualviContents
22-26McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasks15. Connect the product to the customer-supplied Ethernet LAN
2Installation Tasks2-27Installation Tasks• Zone set - A zone set is a group of zones that is activated or deactivated as a single entity across all ma
22-28McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasks4. Route a multimode or singlemode fiber-optic cable (dependi
2Installation Tasks2-29Installation Tasks•Company.•Title.• Telephone and facsimile numbers.Figure 2-14 McDATA Filecenter Home Page3. Complete fields a
22-30McDATA Sphereon 4300 Fabric Switch Installation and Service ManualInstallation Tasks
Maintenance Analysis Procedures3-13Maintenance AnalysisProceduresThis chapter describes maintenance analysis procedures (MAPs) used by service represe
3-2McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis ProceduresQuick StartTable 3-2 lists and summarizes MAPs. Fa
Maintenance Analysis Procedures3-3Maintenence Analysis Procedures071 Switch is isolated. Go to MAP 0600.072 E_Port connected to unsupported switch. Go
3-4McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures410 Switch reset. No action required.411 Firmware
Maintenance Analysis Procedures3-5Maintenence Analysis ProceduresMAP 0000: Start MAPThis MAP describes initial fault isolation beginning at the:•Faile
Figuresvii1-1 Sphereon 4300 Switch (Front View) ... 1-21-2 Sphereon 4300 Switch (Rear View) .
3-6McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures2Ensure the product is connected to facility power
Maintenance Analysis Procedures3-7Maintenence Analysis Procedures↓ Go to step 7.6Inspect the management interface for communication link failure. Obse
3-8McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures8A link incident may have occurred, but the LIN al
Maintenance Analysis Procedures3-9Maintenence Analysis Procedures10Inspect the Event Log to obtain failure reason codes:a. Select Event from the Logs
3-10McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures2The power supply may be disconnected or failed.
Maintenance Analysis Procedures3-11Maintenence Analysis Proceduresb. Byte 0 specifies failed FRU. Byte 1 specifies the slot number of the failed FRU (
3-12McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures2Ensure the product is connected to facility powe
Maintenance Analysis Procedures3-13Maintenence Analysis Proceduresa. Using a Phillips screwdriver, remove the protective cap from the 9-pin maintenanc
3-14McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Proceduresl. Click Yes. A second message box appears. Click
Maintenance Analysis Procedures3-15Maintenence Analysis Procedures2Visual inspection or event code 300, 301, or 302 indicates one or more cooling fans
viiiMcDATA Sphereon 4300 Fabric Switch Installation and Service ManualFigures4-7 Basic Information View ...
3-16McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures4As indicated by event code 426, an intermittent
Maintenance Analysis Procedures3-17Maintenence Analysis Procedures1Ta bl e 3-7 lists event codes, explanations, and MAP steps.Ta bl e 3-8 lists link
3-18McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures2As indicated by event code 080, the eight-byte (
Maintenance Analysis Procedures3-19Maintenence Analysis Procedures4A connection is not allowed because of a conflict with the configured port type. An
3-20McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis ProceduresWas the maintenance action successful?NO YES↓ The
Maintenance Analysis Procedures3-21Maintenence Analysis Procedures6A loopback (wrap) plug is connected to the port with no diagnostic running. Remove
3-22McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures9Inspect and service host bus adapters (HBAs).Was
Maintenance Analysis Procedures3-23Maintenence Analysis Procedures12A connection is not allowed because of a SANtegrity authentication failure. At the
3-24McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis ProceduresChange the port speed to be compatible with the b
Maintenance Analysis Procedures3-25Maintenence Analysis Procedures17As indicated by event code 507, a port failed a loopback test. Reset the failed po
Tablesix2-1 Factory-Set Defaults (Product) ... 2-12-2 Installation Task Summary ...
3-26McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Proceduresd. Unblock the port. Refer to Block or Unblock a
Maintenance Analysis Procedures3-27Maintenence Analysis ProceduresWas the maintenance action successful?NO YES↓ The product port is operational. Exit
3-28McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures2A minor error occurred that caused the Fabric Se
Maintenance Analysis Procedures3-29Maintenence Analysis ProceduresWas the maintenance action successful?NO YES↓ The fabric, ISL, and product are opera
3-30McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Procedures8An E_Port segmented because the error detect tim
Maintenance Analysis Procedures3-31Maintenence Analysis Procedures9An E_Port segmented because two fabric elements had duplicate domain IDs.a. Determi
3-32McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Proceduresb. At the EFCM Basic Edition interface, inspect n
Maintenance Analysis Procedures3-33Maintenence Analysis Proceduresd. At the Switch Priority field, select Principal, Never Principal, or Default, then
3-34McDATA Sphereon 4300 Fabric Switch Installation and Service ManualMaintenence Analysis Proceduresa. At the Event Log, examine the first five bytes
Maintenance Analysis Procedures3-35Maintenence Analysis Procedures• Disconnect the ISL. Exit MAP.• Refer to the manufacturer’s documentation and perfo