Physical Planning Considerations
5-39
Physical Planning Considerations
Remote Fabric
Intrepid 10000 Director LIMs contain two scalable packet processors,
each supporting an optical paddle pair. Each paddle pair provides 16
ports (1.0625 or 2.12500 Gbps operation), four ports (10.2000 Gbps
operation), or ten ports (mixed data rate operation). A minimal
BB_Credit buffer pool is allocated among all paddle-pair ports that
allows a 1.0625 or 2.12500 Gbps port to be set to 60 BB_Credits and a
10.2000 Gbps port to be set to 360 BB_Credits.
With the remote fabric feature installed and enabled, the buffer pool
is increased and each paddle pair is allocated a maximum of 1,373
BB_Credits. Feature enablement allows a long-link 1.0625 or 2.12500
Gbps port to be set to 1133 BB_Credits and a long-link 10.2000 Gbps
port to be set to 1085 BB_Credits. This feature is provided only for the
Intrepid 10000 Director.
N_Port ID
Virtualization
NPIV is a feature that allows a single physical port to support up to
256 virtual Fibre Channel addresses. A virtual node port (NV_Port)
retains full N_Port capabilities and can register for full fabric services.
However, simultaneous loop device operation (NL_Port) and NPIV
operation (NV_Port) is not allowed on the same physical port. This
feature is beneficial in mainframe environments where multiple
partitions share the same physical channel and port connection.
Element Manager
Application
The Element Manager feature allows director or fabric switch
management through an Element Manager application GUI. A
director or switch is delivered with the application enabled for a
31-day grace period. Before grace period expiration, the application
must be reactivated and enabled through a PFE key.
During the grace period, a No Feature Key dialog box appears when
the Element Manager application is accessed. Click OK to close the
dialog box and open the application.
In addition, the message Element Manager license key has not been
installed - Please follow up instructions to update permanent key
appears splashed across views, indicating the Element Manager PFE
key must be installed.