McDATA 1U Server Service Manual Page 355

  • Download
  • Add to my manuals
  • Print
  • Page
    / 430
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 354
A
SBAR Events (600 through 699)
A-61
Event Code Tables
SBAR Events (600 through 699)
Event Code: 600
Message: SBAR hot-insertion initiated.
Severity: Informational
Explanation: Installation of a backup SBAR was initiated with the director powered on and operational. The event indicates that
operational firmware detected the presence of the SBAR, but the SBAR is not seated. When the SBAR is seated
in the director chassis and identified by firmware, an event code 601 is generated.
Action: If event code 601 follows this event and the amber LED on the SBAR extinguishes, the replacement SBAR is
installed and no additional action is required. If event code 601 does not follow this event, re-seat the SBAR. If
event code 601 still does not appear, replace the SBAR.
Event Data: Byte 0 = SBAR slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 601
Message: SBAR hot-insertion completed.
Severity: Informational.
Explanation: An SBAR is installed and recognized by director operational firmware.
Action: No action required.
Event Data: Byte 0 = SBAR slot position.
Bytes 4 - 7 = elapsed millisecond tick count.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident