3-16
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
MAP 0200: POST Failure Analysis
This MAP describes fault isolation for power-on self-test (POST)
failure.Thefailure indicatorareevent codes observed atthe EventLog
(EFCM Basic Edition or Element Manager interface).
1
Table 3-5 lists event codes, explanations, and MAP steps.
2
POST/IPL diagnostics detected a FRU failure.
a. At the
Event Log
, examine the first two bytes (0 and 1) of event
data.
b. Byte 0 indicates the failed component. Byte 1 is the slot number
of the failed FRU (00 for a nonredundant FRU, 00 or 01 for
redundant FRUs, and 00 through 34 for port cards.
Table 3-6 lists byte 0 FRU codes and associated steps that
describe fault isolation procedures.
Table 3-5 MAP 200 Event Codes
Event
Code
Explanation Action
400 Power-up diagnostic failure. Go to step 2.
411 Firmware fault. Go to step 9.
413 Backup CTP card POST failure. Go to step 10.
Table 3-6 MAP 200: Byte 0 FRU Codes
Byte 0 Failed FRU Action
01 Backplane. Go to step 3.
02 CTP card. Go to step 4.
03 SBAR assembly. Go to step 5.
05 Fan module. Go to step 6.
06 Power supply. Go to step 7.
08 - 0F Port card. Go to step 8.
Page view 135