Intrepid® 6140 Director Installation and Service Manual
Installation Tasks
Rack-Mount Installation
Perform the following steps to install and configure up to three
Ethernet hubs in a Fabricenter cabinet or 19-inch equipment rack. A
pointed instrument (pencil tip or bent paper clip), #2 Phillips
screwdriver, and 1/8-inch Allen wrench are required.
1. Secure one mounting bracket to each side of the first hub
(Figure 2-2). Use the two brackets and four pan-head Phillips
screws (8/32 x 0.5-inch) provided.
Figure 2-2 Mounting Bracket Installation (Ethernet Hub)
2. Position the hub in the equipment rack. Align screw holes in the
mounting brackets with screw holes in the rack-mount standards.
3. Secure both sides of the hub to the rack-mount standards. Use the
1/8-inch Allen wrench and four Allen-head mounting screws
(10/32 x 0.5-inch) provided.
4. Repeat step 1 through step 3 for the remaining hubs.
5. To daisy-chain (connect) the hubs:
a. To connect the top and middle stacked hubs, connect an RJ-45
patch cable to port 24 of the top hub, then connect the cable to
port 12 of the middle hub.
b. To connect the bottom and middle stacked hubs, connect a
second RJ-45 patch cable to port 24 ofthemiddlehub,then
connect the cable to port 12 of the bottom hub.