McDATA 1U Server Service Manual Page 156

  • Download
  • Add to my manuals
  • Print
  • Page
    / 430
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 155
3-36
Intrepid® 6140 Director Installation and Service Manual
Maintenence Analysis Procedures
c. The WWN must be entered in (
XX:XX:XX:XX:XX:XX:XX:XX
)
format or must be a valid nickname. Ensure a valid WWN or
nickname is entered.
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
4
A port has an invalid attachment.
a. At the
Event Log
, examine the first five bytes of event data.
b. Byte 0 specifies the port reporting the problem. Byte 4 specifies
the invalid attachment reason (Table 3 -11 ).
Table 3-11 Invalid Attachment Reasons and Actions
Byte 4 Invalid Attachment Reason Action
01 Unknown Contact the next level
of support.
02 ISL connection not allowed. Go to step 5.
03, 04 Incompatible switch. Go to step 6.
05 Loopback plug connected. Go to step 7.
06 N-Port connection not allowed. Go to step 5.
07 Non-McDATA switch at other end. Go to step 6.
08 E_Port capability disabled. Go to step 8.
0A Unauthorized port binding WWN. Go to step 3.
0B Unresponsive node. Go to step 9.
0C ESA security mismatch. Go to step 11.
0D Fabric binding mismatch. Go to step 12.
0E Authorization failure reject. Go to step 9.
Page view 155
1 2 ... 151 152 153 154 155 156 157 158 159 160 161 ... 429 430

Comments to this Manuals