3
3-28
McDATA Sphereon 4400 Fabric Switch Installation and Service Manual
Maintenence Analysis Procedures
2
As indicated by event code 080, the eight-byte (16-digit) worldwide
name (WWN) is not valid or an unconfigured nickname was used.
a. For the product reporting the problem:
EFCM Basic Edition - Select Node List from the Product
menu at any view. The Node List View displays.
Element Manager - Select the Node List tab at any view.
The Node List View displays.
b. At the Port WWN column, inspect the WWN assigned to the port
or attached device.
c. The WWN must be entered in (XX:XX:XX:XX:XX:XX:XX:XX)
format or must be a valid nickname. Ensure a valid WWN or
nickname is entered.
Was the maintenance action successful?
NO YES
The product port is operational. Exit MAP.
Contact the next level of support. Exit MAP.
3
As indicated by event code 081, a port has an invalid attachment.
a. At the Event Log, examine the first five bytes of event data.
b. Byte 0 specifies the port reporting the problem. Byte 4 specifies
the invalid attachment reason as listed in Tab le 3 - 11 .
Link failure - not-operational primitive sequence (NOS) received. Go to step 19.
Link failure - primitive sequence timeout. Go to step 19.
Link failure - invalid primitive sequence received for current link state. Go to step 19.
Table 3-10 Link Incident Messages (Continued)
Explanation Action