Task 4: Configure Product at the EFCM Basic Edition Interface (Optional)
2-21
Installation Tasks
6. Type the case-sensitive user name and password and click OK.
The EFCM Basic Edition interface appears with the Topology View
displaying the status information about each fabric element.
Configure Basic Port
Information
To configure basic port information, use the following steps:
1. Select Basic Info from the Configure menu (Configure>Ports>Basic
Info). The Basic Information View appears(Figure 2-9).
a. Type a port name (24 alphanumeric characters or less) for each
port to be configured in the Name field. The port name should
characterize the device to which the port is attached.
b. Enable the check box in the Blocked column if you want to
block a port (default is unblocked).
c. Disable the check box in the Fabric Address Notify column if
you want to disable the feature (default is enabled). When
enabled, an FL_Port transmits FAN frames after loop
initialization to ensure that FC-AL devices are still logged in.
Figure 2-9 Basic Information View